The New MicroLab 3500 Spirometer
The world’s most versatile portable Spirometer

 

microloop.jpg (3505 bytes) Developed specifically for the professional, the next generation MicroLab employs Micro Direct’s acclaimed precision Gold Standard Digital Volume Transducer which is especially suited to measuring very low flow rates in patients with COPD. The MicroLab has a class-leading, very high definition paper-white screen and can display both Volume/Time and complete Flow/Volume Loops (using either the open or closed loop test techniques).The instrument can measure up to 36 spirometry parameters and has a database storage capacity for over 1000 patients. A built-in high resolution printer quickly delivers hard copy results; however full page printouts are possible using an external Hewlet Packard or Canon printer (compatible models specified by Micro Direct). A new child incentive graphical display is featured and an optional Airway Resistance measurement module is offered. A comprehensive range of advanced features normally only seen on more expensive laboratory based equipment are included (see features and specifications)
 

Features

bulletHigh resolution printer
bulletText entry, enabling comment writing
bulletInternationally recognised on-screen test quality assurance prompts for poor test attempts (e.g. slow start, abrupt end etc.)
bulletBronchodilator and/or steroid assessment
bulletPredicted value and language selection
bulletBody mass index and dyspnoea score calculation
bulletLung age assessment and algorithmic result interpretation by BTS or Enright
bulletFully customisable printout format
bulletComplete with all accessories in a sturdy carry case
 

Specification

Spirometry
Measurements: VC, FEV0.75, FEV1, FEV3, FEV6, FVC, PEF FEV0.75/VC, FEV0.75/FVC, FEV1/VC, FEV1/FVC,
FEV3/VC, FEV3/FVC, FEV0.75/FEV6, FEV1/FEV6, MEF75, MEF50, MEF25, MEF25-75,
FEF50/VC, FEF50FVC, MVVind, FET, MET, IC, FIV1, FIVC, PIF, FIV1,/FIVC, FIF25, FIF50,
FIF75, FIF50/MEF50,VT, ERV, IRV [all expiratory measurements with baseline, post
bronchodilator 1 and 2, % predicted, % change and normal range]
Tests per subject: VC-unlimited (best reported) FVC-unlimited (best 3 from baseline, post 1
and post 2 tests)
Predicted Values: Knudson or Crapo
Transducer: Micro Direct Gold Standard Bi-Directional Digital Volume
Resolution: 10ml volume 0.03l/s flow
Accuracy: +/-3%.To ATS recommendations – Standardisation of spirometry 1994 update for
flows and volumes
General
Storage: 1000 patients’ tests including Flow/Volume loops and Volume/Time curves
Printer Output: 320 dot internal thermal printer, or serial output for all IBM Proprinter compatible
Canon bubble jet printers e.g. BJC250, BJC4400, BJC80 and BJC50, and all PLC3
compatible Hewlett Packard printers e.g. Deskjet 420, 695, 340, 880C and 895Cxi
Display: High resolution graphic LCD 240 x 160 pixels
Power Supply: 100 – 240V 0.3A 47 – 63Hz. DC output 9V 0.8A
Battery Pack: Rechargeable NiCad 7.2V 600mA/hours
Dimensions: 6" x 10" x 1.5".Transducer 2"x 2"x 3.5"
Weight: Unit weight 1 lb 10 oz. Packed weight 5 lb 10 oz.
Temperature: 32 to +104 F
Operating Humidity: 30% to 90% RH
Storage Temperature: 0 to +158 F
Storage Humidity: 10% to 90% RH

 