SmartSat
Pulse Oximetry AnalyzerThe SmartSat Pulse Oximetry Analyzer
is the only tester that does the complete job by providing the industry's first Probe
Analyzer. The Probe Analyzer includes a Probe Continuity Test that tests
the probe independently and can thus isolate opens and shorts. Since most pulse oximetry
failures are ultimately traced to the probe, SmartSatŐs Probe Analyzer can
save you hours of troubleshooting time.
When you need a SpO2 simulator,
why fool around with testers that use the optical "finger" simulation method?
Most pulse oximeter manufacturers do not endorse optical finger simulation because it can
actually introduce uncertainty into the SpO2 simulation test. SmartSat
is the only universal SpO2 simulator, which uses the manufacturer-approved
"direct electrical simulation" method to provide unmatched accuracy and
reliability. In fact, SmartSat is used by leading pulse oximeter manufacturers and
is emerging as the industry standard pulse oximetry tester.
SmartSat also allows you to document
your test results efficiently. Automatic Data-Logging provides closed loop testing via a
serial cables between SmartSat and the pulse oximeter. After testing, you can
either print the results immediately or use Stored Printing to save the results for
printing or up-loading at a later time. SmartSat can even up-load test results into
popular equipment management programs such as Otis®/Profile® and medTester/ Sentinel.
FEATURES
| Probe Continuity Test
|
| Direct Electrical Simulation
|
| Automatic Data-Logging
|
| Stored Printing
|
| Otis®/medTester Compatible
|
SPECIFICATIONS
SpO2 Simulator |
Oxygen Saturation (SpO2)
Range: 0 - 100 SpO2%
Resolution: 1 SpO2%
Accuracy:
±0.5% SpO2%, 70 - 100 SpO2%
±1 SpO2%, 50 - 69 SpO2% Pulse Rate
Range: 20 - 255 bpm
Resolution: 1 bpm
Accuracy:
±1 bpm, 20 - 199 bpm
±2 bpm, 200 - 255 bpm
R-Curves (Red/IR Ratio)
R-curves specify the relationship between the Red/IR ratio measured by pulse oximeters and
the SpO2 value displayed. R-curves are obtained by each pulse oximeter
manufacturer during clinical trials.
Preset Manufacturer's R-Curves (10):
BCI, Criticare, Datascope, Datex, Hewlett-Packard, Nellcor, Nihon Kohden, Nonin,
Novametrix & Ohmeda.
Plethysmographic Amplitude
Simulates the effect of tissue perfusion.
Range: 0 - 200% of nominal amplitude
Resolution: 1%
Accuracy: ±1%
Ambient Light
Simulates the ambient light level "seen" by the oximeter probe.
Range:
DC Level: 0 - 255%
AC Level: 0 - 255%
Resolution: 1%
Accuracy: ±1%
Flicker Frequency Presets (6):
60 Hz; 120 Hz; 121 H; 50 Hz; 100 Hz; 101 Hz
Motion Artifact
Amplitude Range: 0 - 100
Frequency: 4Hz, (Contact factory for availability of other frequencies). |
|
Arrhythmias
Simulates cardiac arrhythmias by altering the plethysmographic pulse amplitude and pulse
rate.
Arrhythmias (5): Asystolic Pause; PVC; Atrial Fibrillation; Tachycardia;
Bradycardia Auto
Sequences
Preset Auto Sequences automate pulse oximeter testing
Standard Presets (5):
CalDown - |
decreasing SpO2 and increasing Pulse Rate at 20 second intervals |
CalUp - |
increasing SpO2 and decreasing Pulse Rate at 20 second intervals |
CalLong - |
decreasing SpO2 and increasing Pulse Rate at 30 seconds intervals |
FullSwp - |
test every SpO2 point between 60 and 100 at 21 second intervals. |
Trend - |
Sleep Apnea pattern over 60 minutes |
Automatic Data-Logging & Printing
Closed-loop testing of pulse oximeters can be achieved by connecting a cable between the
"SERIAL COMM" port of the oximeter and the "RS-232" port of the
SmartSat. Oximeter test results are automatically retrieved and displayed on the SmartSat
screen; the test results can be printed immediately or stored for future printing. Serial
data protocols supported: BCI, Criticare, Datascope, Datex, Hewlett-Packard, Nellcor,
Nihon Kohden, Nonin, Novametrix & Ohmeda. (Please contact the factory for the
availability of other serial data protocols).
Stored Printing
Stored Printing allows the user to save test results for printing at a later time or
up-loading into popular equipment management programs such as Otis®/Profile® and
medTester/Sentinel.
Remote Control
The SmartSat can be operated via remote control through its RS-232 port. In addition to
duplicating all front panel operations, remote control commands include status query
commands, a keypad lock command and a "warm-boot" command. |
Probe Analyzer - Probe Continuity Test |
Simultaneous Channels:
2 for Nellcor-style probes:
LED & PhotoDiode circuits
3 for Ohmeda-style probes:
Red LED, IR, LED & PhotoDiode circuits
Test Mode:
Constant Current Stimulus, Voltage output |
|
Constant Current Stimulus: 500 uA
Intermittent "Glitch" Defection:
Detect open circuits and short circuits, 1 msec or longer
Probe Connection:
Connectors for Nellcor & Ohmeda probes are built into SmartSat; other probes are
connected via adapter cables. |
General |
Display
Type: Backlit graphic LCD Resolution: 320
h x 240 v, 0.30mm dot pitch
Controls: Contrast, Backlight Timeout
Serial Interface
Type: RS-232C, 9 pin "PC-AT" style
Baud Rates: 300 - 9600 bps
Modes: Remote Control, Data-Logging & Equipment Management Up-Loading
Printer Interface
Type: Centronics, 25 pin "IBM-PC" style
Battery & AC Adapter
Battery
Type: Nickel Cadmium
Voltage: 19.2V
Capacity: 1.2A-Hr (About 3 hours usage)
Charge Time: 12 Hours (charges even if SmartSat in use)
External AC Adapter
Type: Wallmount Linear
Input: 115VAC, 60Hz or 230VAC, 50Hz
Output: 24VDC, 500mA
Safety Agency Approvals: UL, CSA, TUV |
|
Physical
Case: Aluminum with non-skid feet & handle
Dimensions: 8" Wide x 8" Deep x 5" High
Weight: 4 lbs. Including battery
Standard Accessories
SpO2 Simulator Adapter Cables:
BCI, Criticare, Datascope, Datex, Hewlett-Packard, Nellcor, Nihon Kohden Nonin, Novametrix
& Ohmeda.
Probe Analyzer Adapter Cables:
Criticare, Datascope, Datex, Hewlett-Packard, Nihon Kohden,
Novametrix.Note: BCI, Nellcor, Nonin & Ohmeda probes connect directly.
Optional Accessories
Automatic Data-Logging Cables:
BCI, Criticare, Datascope, Datex, Hewlett-Packard, Nellcor, Nihon Kohden,
Nonin, Novametrix & Ohmeda
SmartSat Carry Case
Otis/medTester Interface:
SmartSat can up-load test results into Otis¨/Profile¨ and
medTester/Sentinel equipment management systems. |
SmartSat ORDERING
INFORMATION |
CAT.
NO. |
DESCRIPTION |
VSmartSat |
SmartSat Pulse Oximetry Analyzer |
SmartSat is a trademark of Clinical
Dynamics Corporation.
SmartSat is manufactured by Clinical Dynamics Corporation.